Effectiveness of uterine tamponade devices for refractory postpartum haemorrhage after vaginal birth: a systematic review

Instituto de Efectividad Clínica y Sanitaria (IECS-CONICET), Buenos Aires, Argentina. UNDP-UNFPA-UNICEF-WHO-World Bank Special Program of Research, Development, and Research Training in Human Reproduction (HRP), Department of Sexual and Reproductive Health and Research, World Health Organization, Geneva, Switzerland. University of Botswana, Gaborone, Botswana. Effective Care Research Unit, University of the Witwatersrand/Walter Sisulu University, South Africa. Université de Paris, U1153 Centre for Epidemiology and Statistics Sorbonne Paris Cité (CRESS), Obstetrical Perinatal and Pediatric Epidemiology Research Team, EPOPé, INSERM, INRA, Paris, France. Concept Foundation, Geneva, Switzerland. Department of Obstetrics, Birth Centre Wilhelmina's Children Hospital, Division Woman and Baby, University Medical Center Utrecht, the Netherlands.

BJOG : an international journal of obstetrics and gynaecology. 2021
Abstract
OBJECTIVES To evaluate uterine tamponade devices' effectiveness for atonic refractory postpartum haemorrhage (PPH) after vaginal birth and the effect of including them in institutional protocols. SEARCH STRATEGY PubMed, EMBASE, CINAHL, LILACS, POPLINE, from inception to January 2021. STUDY SELECTION randomised and non-randomised comparative studies. OUTCOMES composite outcome including surgical interventions (artery ligations, compressive sutures or hysterectomy) or maternal death, and hysterectomy. RESULTS all included studies were at high risk of bias. The certainty of the evidence was rated as very low to low. One randomised study measured the effect of the condom-catheter balloon compared to standard care and found unclear results for the composite outcome (RR 2.33, 95%CI 0.76-7.14) and hysterectomy (RR 4.14, 95%CI 0.48-35.93). Three comparative studies assessed the effect of including UBTs in institutional protocols. A stepped wedge cluster RCT suggested an increase in the composite outcome (RR 4.08, 95%CI 1.07-15.58) and unclear results for hysterectomy (RR 4.38, 95% CI 0.47-41.09) with the use of the condom-catheter or surgical glove balloon. One non-randomised study showed unclear effects on the composite outcome (RR 0.33, 95%CI 0.11-1.03) and hysterectomy (RR 0.49, 95%CI 0.04-5.38) after the inclusion of the Bakri balloon. The second non-randomised study found unclear effects on the composite outcome (RR 0.95, 95%CI 0.32-2.81) and hysterectomy (RR 1.84, 95%CI 0.44-7.69) after the inclusion of Ebb or Bakri balloon. CONCLUSIONS the effect of uterine tamponade devices for the management of atonic refractory PPH after vaginal delivery is unclear, as is the role of the type of device and the setting.
Study details
Study Design : Systematic Review
Language : eng
Credits : Bibliographic data from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine