Local administration of epsilon-aminocaproic acid reduces post-operative blood loss from surgery for closed, Sanders III-IV calcaneal fractures

Department of Bone and joint surgery, People's Hospital of Leshan, Shizhong District, Leshan, 614000, Sichuan Province, People's Republic of China. Department of Bone and Joint Surgery, Affiliated Hospital of Southwest Medical University, No 25 Tai Ping Street, Luzhou, 643000, Sichuan Province, People's Republic of China. Department of Bone and joint surgery, People's Hospital of Leshan, Shizhong District, Leshan, 614000, Sichuan Province, People's Republic of China. 275817565@qq.com.

International orthopaedics. 2022
Abstract
PURPOSE To investigate whether local administration of epsilon-aminocaproic acid (EACA) is effective and safe in reducing the post-operative blood loss in surgery for Sanders III-IV calcaneal fractures. METHODS Patients with Sanders III-IV calcaneal fractures who were hospitalized in our hospital from January 2016 to February 2021 and underwent open reduction internal fixation (ORIF) via lateral approach with an L-shaped incision were included in the current study. Eighty five patients were randomly divided into two groups, EACA group (43) and control group (42). Twenty milliliters of 5% EACA solution or normal saline was perfused into the incision of patients in EACA group and control group, respectively. The volume of post-operative drainage was investigated as the primary outcome. Post-operative blood test, coagulation test, and wound complications were analyzed as the secondary outcomes. RESULTS The volume of post-operative drainage at 24 and 48 h was 164.8 ± 51.4 ml, 18.9 ± 3.8 ml for patients in EACA group, and 373.0 ± 88.1 ml, 21.2 ± 4.4 ml for patients in the control group, respectively. EACA greatly reduced the post-operative blood loss compared to the control (normal saline). The difference between the two groups was statistically significant. No statistically significant difference was found between EACA group and control group with regard to the pre-operative, baseline characteristics. Post-operative blood test results demonstrated that haemoglobin and hematocrit were significantly higher in EACA compared to those of control group. No significant difference was found between EACA group and control group in terms of the platelet counts, prothrombin time (P.T.), activated partial prothrombin time (APTT), and wound complications. CONCLUSION Local administration of EACA is effective in post-operative blood loss reduction in ORIF surgeries for Sanders III-IV types of calcaneal fractures without increasing the incidence of periwound complication.
Study details
Language : eng
Credits : Bibliographic data from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine