1.
Comparison of fibrin sealants in peripheral vascular surgery: A systematic review and network meta-analysis
Danker Iii W, DeAnglis A, Ferko N, Garcia D, Hogan A
Annals of medicine and surgery (2012). 2021;61:161-168
Abstract
BACKGROUND Evidence comparing fibrin sealants (FSs) in surgery are limited. This study evaluated the efficacy and safety of FSs, and manual compression in peripheral vascular surgery. METHODS A systematic review of randomized trials was conducted in Medline, Embase, and Cochrane databases within the last 15 years. Data were available to conduct a network meta-analysis (NMA) in peripheral vascular surgery. Fibrin sealant treatment arms were further broken-down and assessed by clotting time (i.e., 2-min [2C] or 1-min [1C]). The primary efficacy outcome was the proportion of patients achieving hemostasis by 4 min (T4). Treatment-related serious and non-serious adverse events (AEs) were qualitatively assessed. RESULTS Five studies (n = 693), were included in the NMA. Results predicted VISTASEAL 2C, followed by EVICEL 1C, had the highest probability of achieving T4. Compared with manual compression, significant improvements in T4 were found with VISTASEAL 2C (relative risk [RR] = 2.67, 95% CrI: 2.13-3.34), EVICEL 1C (RR = 2.58, 95% CrI: 2.04-3.23), VISTASEAL 1C (RR = 2.00, 95% CrI: 1.45-2.65), and TISSEEL 2C (RR = 1.99, 95% CrI: 1.48-2.60). TISSEEL 1C was not significantly different than manual compression (RR = 1.40, 95% CrI: 0.70-2.33). Among FSs, VISTASEAL 2C was associated with a significant improvements in T4 compared with VISTASEAL 1C (RR = 1.33, 95% CrI: 1.02-1.82), TISSEEL 2C (RR = 1.34, 95% CrI: 1.05-1.77), and TISSEEL 1C (RR = 1.90, 95% CrI: 1.18-3.74). Treatment-related serious and non-serious AE rates were typically lower than 2%. CONCLUSIONS In peripheral vascular surgeries, VISTASEAL 2C and EVICEL 1C were shown to have the highest probabilities for achieving rapid hemostasis among the treatments compared. Future studies should expand networks across surgery types as data become available.
2.
Platelet Transfusion in Cardiac Surgery: A Systematic Review and Meta-Analysis
Yanagawa B, Ribeiro R, Lee J, Mazer CD, Cheng D, Martin J, Verma S, Friedrich JO
Ann Thorac Surg. 2020
Abstract
BACKGROUND Blood transfusion is a well-established independent risk factor for mortality in patients undergoing cardiac surgery but the impact of platelet transfusion is less clear. We performed a systematic review and meta-analysis of observational studies comparing outcomes of patients who received platelet transfusion following cardiac surgery. METHODS We searched MEDLINE and EMBASE databases to January 2019 for studies comparing peri-operative outcomes in patients undergoing cardiac surgery with and without platelet transfusion. RESULTS There were 9 observational studies reporting on 101,511 patients: 12% with and 88% without platelet transfusion. In unmatched/unadjusted studies, patients who received platelet transfusion were older with greater incidence of renal, peripheral and cerebrovascular disease, myocardial infarction, left ventricular dysfunction, and anemia. They were more likely to have non-elective, combined surgery; pre-operative hemodynamic instability and endocarditis; and more likely to be on clopidogrel preoperatively. Perioperative complications were significantly increased without adjusting for these baseline differences. After pooling only matched/adjusted data, differences were not found in patients who did vs did not receive platelets for operative mortality (risk ratio [RR] 1.26, 95%CI:0.69-2.32, p=0.46, 5 studies), stroke (RR 0.94, 95%CI:0.62-1.45, p=0.79, 5 studies), myocardial infarction (RR1.29, 95%CI:0.95-1.77, p=0.11, 3 studies), reoperation for bleeding (RR1.20, 95%CI:0.46-3.18, p=0.71, 3 studies), infection (RR1.02, 95%CI:0.86-1.20, p=0.85, 6 studies), and peri-operative dialysis (RR0.91, 95%CI:0.63-1.32, p=0.62, 3 studies). CONCLUSIONS After accounting for baseline differences, platelet transfusion was not linked with perioperative complications in cardiac surgery patients. Given the small number of observational studies, these findings should be considered hypothesis generating.
3.
A meta-analysis of platelet gel for prevention of sternal wound infections following cardiac surgery
Kirmani BH, Jones SG, Datta S, Mclaughlin EK, Hoschtitzky AJ
Blood Transfusion = Trasfusione Del Sangue. 2016;:1-9.
Abstract
Deep sternal wound infection and bleeding are devastating complications following cardiac surgery, which may be reduced by topical application of autologous platelet gel. Systematic review identified seven comparative studies involving 4,692 patients. Meta-analysis showed significant reductions in all sternal wound infections (odds ratio 3.48 [1.08-11.23], p=0.04) and mediastinitis (odds ratio 2.69 [1.20-6.06], p=0.02) but not bleeding. No adverse events relating to the use of topical platelet-rich plasma were reported. The use of autologous platelet gel in cardiac surgery appears to provide significant reductions in serious sternal wound infections, and its use is unlikely to be associated with significant risk.