1.
Are thromboelastometric and thromboelastographic parameters associated with mortality in septic patients? A systematic review and meta-analysis
Boscolo A, Spiezia L, De Cassai A, Pasin L, Pesenti E, Zatta M, Zampirollo S, Andreatta G, Sella N, Pettenuzzo T, et al
Journal of critical care. 2020;61:5-13
Abstract
BACKGROUND Thromboelastometry/elastography (ROTEM/TEG) showed promising results for diagnosis of sepsis-induced coagulopathy, but their association with the outcome is unclear. Our aim was to assess any difference in ROTEM/TEG measurements between septic survivors and non-survivors. METHODS Pubmed, Web of Science, Embase and Cochrane Library databases were investigated. The research aimed to include any randomized or observational study: i) on septic adult patients admitted to Intensive Care Unit (ICU) or Emergency Department (ED); ii) including ROTEM/TEG; iii) assessing mortality. RESULTS Seven prospective and four retrospective observational studies (952 patients) were included. According to the INTEM/kaolin-assay, clotting time (CT)/R (standardized mean difference(SMD) -0.29, 95% CI -0.49 to -0.09, p = 0.004) and clot formation time (CFT)/K (SMD -0.42, 95% CI -0.78 to -0.06, p = 0.02) were shorter in survivors. According to the EXTEM-assay, CT was shorter (MD -11.66 s, 95% CI -22.59 to -0.73, p = 0.04), while MCF was higher (MD 3.49 mm, 95% CI 0.43 to 6.55, p = 0.03) in survivors. A hypocoagulable profile was more frequent in non-survivors (OR 0.31, 95%CI 0.18 to 0.55, p < 0.0001). Overall, the risk of bias of the included studies was moderate and the quality of evidence low. CONCLUSIONS Hypocoagulability and lower MCF in EXTEM may be associated with higher mortality in sepsis.
2.
Utility of thromboelastography and/or thromboelastometry in adults with sepsis: a systematic review
Muller MC, Meijers JC, Vroom MB, Juffermans NP
Critical Care (London, England). 2014;18((2):):R30.
Abstract
INTRODUCTION Coagulation abnormalities are frequent in sepsis. Conventional coagulation assays, however, have several limitations. A surge of interest exists in the use of point-of-care tests to diagnose hypo- and hypercoagulability in sepsis. METHODS MEDLINE, EMBASE, and the Cochrane Library were searched from 1 January 1980 to 31 December 2012. The search was limited to adults, and language was limited to English. Reference lists of retrieved articles were hand-searched for additional studies. Ongoing trials were searched on http://www.controlled-trials.com and http://www.clinicaltrials.gov. Studies addressing TEG/ROTEM measurements in adult patients with sepsis admitted to the ICU were considered eligible. RESULTS Of 680 screened articles, 18 studies were included, of which two were randomized controlled trials, and 16 were observational cohort studies. In patients with sepsis, results show both hyper- and hypocoagulability, as well as TEG/ROTEM values that fell within reference values. Both hyper- and hypocoagulability were to some extent associated with diffuse intravascular coagulation. Compared with conventional coagulation tests, TEG/ROTEM can detect impaired fibrinolysis, which can possibly help to discriminate between sepsis and systemic inflammatory response syndrome (SIRS). A hypocoagulable profile is associated with increased mortality. The value of TEG/ROTEM to identify patients with sepsis who could possibly benefit from therapies interfering with the coagulation system could not be assessed, because studies addressing this topic were limited. CONCLUSION TEG/ROTEM could be a promising tool in diagnosing alterations in coagulation in sepsis. Further research on the value of TEG/ROTEM in these patients is warranted. Given that coagulopathy is a dynamic process, sequential measurements are needed to understand the coagulation patterns in sepsis, as can be detected by TEG/ROTEM.