1.
Prophylactic plasma transfusion for patients without inherited bleeding disorders or anticoagulant use undergoing non-cardiac surgery or invasive procedures
Huber J, Stanworth SJ, Doree C, Fortin PM, Trivella M, Brunskill SJ, Hopewell S, Wilkinson KL, Estcourt LJ
The Cochrane database of systematic reviews. 2019;11:Cd012745
Abstract
BACKGROUND In the absence of bleeding, plasma is commonly transfused to people prophylactically to prevent bleeding. In this context, it is transfused before operative or invasive procedures (such as liver biopsy or chest drainage tube insertion) in those considered at increased risk of bleeding, typically defined by abnormalities of laboratory tests of coagulation. As plasma contains procoagulant factors, plasma transfusion may reduce perioperative bleeding risk. This outcome has clinical importance given that perioperative bleeding and blood transfusion have been associated with increased morbidity and mortality. Plasma is expensive, and some countries have experienced issues with blood product shortages, donor pool reliability, and incomplete screening for transmissible infections. Thus, although the benefit of prophylactic plasma transfusion has not been well established, plasma transfusion does carry potentially life-threatening risks. OBJECTIVES To determine the clinical effectiveness and safety of prophylactic plasma transfusion for people with coagulation test abnormalities (in the absence of inherited bleeding disorders or use of anticoagulant medication) requiring non-cardiac surgery or invasive procedures. SEARCH METHODS We searched for randomised controlled trials (RCTs), without language or publication status restrictions in: Cochrane Central Register of Controlled Trials (CENTRAL; 2017 Issue 7); Ovid MEDLINE (from 1946); Ovid Embase (from 1974); Cumulative Index to Nursing and Allied Health Literature (CINAHL; EBSCOHost) (from 1937); PubMed (e-publications and in-process citations ahead of print only); Transfusion Evidence Library (from 1950); Latin American Caribbean Health Sciences Literature (LILACS) (from 1982); Web of Science: Conference Proceedings Citation Index-Science (CPCI-S) (Thomson Reuters, from 1990); ClinicalTrials.gov; and World Health Organization (WHO) International Clinical Trials Registry Search Platform (ICTRP) to 28 January 2019. SELECTION CRITERIA We included RCTs comparing: prophylactic plasma transfusion to placebo, intravenous fluid, or no intervention; prophylactic plasma transfusion to alternative pro-haemostatic agents; or different haemostatic thresholds for prophylactic plasma transfusion. We included participants of any age, and we excluded trials incorporating individuals with previous active bleeding, with inherited bleeding disorders, or taking anticoagulant medication before enrolment. DATA COLLECTION AND ANALYSIS We used standard methodological procedures expected by Cochrane. MAIN RESULTS We included five trials in this review, all were conducted in high-income countries. Three additional trials are ongoing. One trial compared fresh frozen plasma (FFP) transfusion with no transfusion given. One trial compared FFP or platelet transfusion or both with neither FFP nor platelet transfusion given. One trial compared FFP transfusion with administration of alternative pro-haemostatic agents (factors II, IX, and X followed by VII). One trial compared the use of different transfusion triggers using the international normalised ratio measurement. One trial compared the use of a thromboelastographic-guided transfusion trigger using standard laboratory measurements of coagulation. Four trials enrolled only adults, whereas the fifth trial did not specify participant age. Four trials included only minor procedures that could be performed by the bedside. Only one trial included some participants undergoing major surgical operations. Two trials included only participants in intensive care. Two trials included only participants with liver disease. Three trials did not recruit sufficient participants to meet their pre-calculated sample size. Overall, the quality of evidence was low to very low across different outcomes according to GRADE methodology, due to risk of bias, indirectness, and imprecision. One trial was stopped after recruiting two participants, therefore this review's findings are based on the remaining four trials (234 participants). When plasma transfusion was compared with no transfusion given, we are very uncertain whether there was a difference in 30-day mortality (1 trial comparing FFP or platelet transfusion or both with neither FFP nor platelet transfusion, 72 participants; risk ratio (RR) 0.38, 95% confidence interval (CI) 0.13 to 1.10; very low-quality evidence). We are very uncertain whether there was a difference in major bleeding within 24 hours (1 trial comparing FFP transfusion vs no transfusion, 76 participants; RR 0.33, 95% CI 0.01 to 7.93; very low-quality evidence; 1 trial comparing FFP or platelet transfusion or both with neither FFP nor platelet transfusion, 72 participants; RR 1.59, 95% CI 0.28 to 8.93; very low-quality evidence). We are very uncertain whether there was a difference in the number of blood product transfusions per person (1 trial, 76 participants; study authors reported no difference; very low-quality evidence) or in the number of people requiring transfusion (1 trial comparing FFP or platelet transfusion or both with neither FFP nor platelet transfusion, 72 participants; study authors reported no blood transfusion given; very low-quality evidence) or in the risk of transfusion-related adverse events (acute lung injury) (1 trial, 76 participants; study authors reported no difference; very low-quality evidence). When plasma transfusion was compared with other pro-haemostatic agents, we are very uncertain whether there was a difference in major bleeding (1 trial; 21 participants; no events; very low-quality evidence) or in transfusion-related adverse events (febrile or allergic reactions) (1 trial, 21 participants; RR 9.82, 95% CI 0.59 to 162.24; very low-quality evidence). When different triggers for FFP transfusion were compared, the number of people requiring transfusion may have been reduced (for overall blood products) when a thromboelastographic-guided transfusion trigger was compared with standard laboratory tests (1 trial, 60 participants; RR 0.18, 95% CI 0.08 to 0.39; low-quality evidence). We are very uncertain whether there was a difference in major bleeding (1 trial, 60 participants; RR 0.33, 95% CI 0.01 to 7.87; very low-quality evidence) or in transfusion-related adverse events (allergic reactions) (1 trial; 60 participants; RR 0.33, 95% CI 0.01 to 7.87; very low-quality evidence). Only one trial reported 30-day mortality. No trials reported procedure-related harmful events (excluding bleeding) or quality of life. AUTHORS' CONCLUSIONS Review findings show uncertainty for the utility and safety of prophylactic FFP use. This is due to predominantly very low-quality evidence that is available for its use over a range of clinically important outcomes, together with lack of confidence in the wider applicability of study findings, given the paucity or absence of study data in settings such as major body cavity surgery, extensive soft tissue surgery, orthopaedic surgery, or neurosurgery. Therefore, from the limited RCT evidence, we can neither support nor oppose the use of prophylactic FFP in clinical practice.
2.
Fresh frozen plasma for cardiovascular surgery
Desborough M, Sandu R, Brunskill SJ, Doree C, Trivella M, Montedori A, Abraha I, Stanworth S
Cochrane Database of Systematic Reviews.. 2015;((7)):CD007614.
Abstract
BACKGROUND Fresh frozen plasma (FFP) is a blood component containing procoagulant factors, which is sometimes used in cardiovascular surgery with the aim of reducing the risk of bleeding. The purpose of this review is to assess the risk of mortality for patients undergoing cardiovascular surgery who receive FFP. OBJECTIVES To evaluate the risk to benefit ratio of FFP transfusion in cardiovascular surgery for the treatment of bleeding patients or for prophylaxis against bleeding. SEARCH METHODS We searched 11 bibliographic databases and four ongoing trials databases including the Cochrane Central Register of Controlled Trials (CENTRAL, Issue 3, 2015), MEDLINE (OvidSP, 1946 to 21 April 2015), EMBASE (OvidSP, 1974 to 21 April 2015), PubMed (e-publications only: searched 21 April 2015), ClinicalTrials.gov, World Health Organization (WHO) ICTRP and the ISRCTN Register (searched 21 April 2015). We also searched the references of all identified trials and relevant review articles. We did not limit the searches by language or publication status. SELECTION CRITERIA We included randomised controlled trials in patients undergoing major cardiac or vascular surgery who were allocated to a FFP group or a comparator (no plasma or an active comparator, either clinical plasma (any type) or a plasma-derived blood product). We included participants of any age (neonates, children and adults). We excluded studies of plasmapheresis and plasma exchange. DATA COLLECTION AND ANALYSIS Two authors screened all electronically derived citations and abstracts of papers identified by the review search strategy. Two authors assessed risk of bias in the included studies and extracted data independently. We took care to note whether FFP was used therapeutically or prophylactically within each trial. MAIN RESULTS We included 15 trials, with a total of 755 participants for analysis in the review. Fourteen trials compared prophylactic use of FFP against no FFP. One study compared therapeutic use of two types of plasma. The timing of intervention varied, including FFP transfusion at the time of heparin neutralisation and stopping cardiopulmonary bypass (CPB) (seven trials), with CPB priming (four trials), after anaesthesia induction (one trial) and postoperatively (two trials). Twelve trials excluded patients having emergency surgery and nine excluded patients with coagulopathies.Overall the trials were small, with only four reporting an a priori sample size calculation. No trial was powered to determine changes in mortality as a primary outcome. There was either high risk of bias, or unclear risk, in the majority of trials included in this review.There was no difference in the number of deaths between the intervention arms in the six trials (with 287 patients) reporting mortality (very low quality evidence). There was also no difference in blood loss in the first 24 hours for neonatal/paediatric patients (four trials with 138 patients; low quality evidence): mean difference (MD) -1.46 ml/kg (95% confidence interval (CI) -4.7 to 1.78 ml/kg); or adult patients (one trial with 120 patients): MD -12.00 ml (95% CI -101.16 to 77.16 ml).Transfusion with FFP was inferior to control for preventing patients receiving any red cell transfusion: Peto odds ratio (OR) 2.57 (95% CI 1.30 to 5.08; moderate quality evidence). There was a difference in prothrombin time within two hours of FFP transfusion in eight trials (with 210 patients; moderate quality evidence) favouring the FFP arm: MD -0.71 seconds (95% CI -1.28 to -0.13 seconds). There was no difference in the risk of returning to theatre for reoperation (eight trials with 398 patients; moderate quality evidence): Peto OR 0.81 (95% CI 0.26 to 2.57). Only one included study reported adverse events as an outcome and reported no significant adverse events following FFP transfusion. AUTHORS' CONCLUSIONS This review has found no evidence to support the prophylactic administration of FFP to patients without coagulopathy undergoing elective cardiac surgery. There was insufficient evidence about treatment of p
3.
Is fresh frozen plasma clinically effective? A systematic review of randomized controlled trials
Stanworth SJ, Brunskill SJ, Hyde CJ, McClelland DL, Murphy MF
British Journal of Haematology. 2004;126((1):):139-152.
-
-
-
Free full text
-
Full text
-
Editor's Choice
Abstract
Summary: Randomized controlled trials of good quality are a recognized means to robustly assess the efficacy of interventions in clinical practice. A systematic identification and appraisal of all randomized trials involving fresh frozen plasma (FFP) has been undertaken in parallel to the drafting of the updated British Committee for Standards in Haematology guidelines on the use of FFP. A total of 57 trials met the criteria for inclusion in the review. Most clinical uses of FFP, currently recommended by practice guidelines, are not supported by evidence from randomized trials. In particular, there is little evidence for the effectiveness of the prophylactic use of FFP. Many published trials on the use of FFP have enrolled small numbers of patients, and provided inadequate information on the ability of the trial to detect meaningful differences in outcomes between the two patient groups. Other concerns about the design of the trials include the dose of FFP used, and the potential for bias. No studies have taken adequate account of the extent to which adverse effects might negate the clinical benefits of treatment with FFP. There is a need to consider how best to develop new trials to determine the efficacy of FFP in different clinical scenarios to provide the evidence base to support national guidelines for transfusion practice. Trials of modified FFP (e.g. pathogen inactivated) are of questionable value when there is little evidence that the standard product is an effective treatment.
PICO Summary
Population
Patients enrolled in randomised controlled trials (RCTs) for different types of fresh frozen plasma (FFP) usage, (57 RCTs).
Intervention
Fresh frozen plasma.
Comparison
Various comparators, including: no FFP/plasma; a non-blood product; a different blood product; different formulations of FFP.
Outcome
Most clinical uses of FFP, recommended by practice guidelines, were not supported by evidence from randomized trials. In particular, there was little evidence for the effectiveness of the prophylactic use of FFP. Many published trials on the use of FFP enrolled small numbers of patients, and provided inadequate information on the ability of the trial to detect meaningful differences in outcomes between the two patient groups. Other concerns about the design of the trials included the dose of FFP used, and the potential for bias. No studies took adequate account of the extent to which adverse effects might negate the clinical benefits of treatment with FFP.