1.
Daprodustat for the Treatment of Anemia in Patients Undergoing Dialysis
Singh AK, Carroll K, Perkovic V, Solomon S, Jha V, Johansen KL, Lopes RD, Macdougall IC, Obrador GT, Waikar SS, et al
The New England journal of medicine. 2021
-
-
-
-
Editor's Choice
Abstract
BACKGROUND Among patients with chronic kidney disease (CKD), the use of recombinant human erythropoietin and its derivatives for the treatment of anemia has been linked to a possibly increased risk of stroke, myocardial infarction, and other adverse events. Several trials have suggested that hypoxia-inducible factor (HIF) prolyl hydroxylase inhibitors (PHIs) are as effective as erythropoiesis-stimulating agents (ESAs) in increasing hemoglobin levels. METHODS In this randomized, open-label, phase 3 trial, we assigned patients with CKD who were undergoing dialysis and who had a hemoglobin level of 8.0 to 11.5 g per deciliter to receive an oral HIF-PHI (daprodustat) or an injectable ESA (epoetin alfa if they were receiving hemodialysis or darbepoetin alfa if they were receiving peritoneal dialysis). The two primary outcomes were the mean change in the hemoglobin level from baseline to weeks 28 through 52 (noninferiority margin, -0.75 g per deciliter) and the first occurrence of a major adverse cardiovascular event (a composite of death from any cause, nonfatal myocardial infarction, or nonfatal stroke), with a noninferiority margin of 1.25. RESULTS A total of 2964 patients underwent randomization. The mean (±SD) baseline hemoglobin level was 10.4±1.0 g per deciliter overall. The mean (±SE) change in the hemoglobin level from baseline to weeks 28 through 52 was 0.28±0.02 g per deciliter in the daprodustat group and 0.10±0.02 g per deciliter in the ESA group (difference, 0.18 g per deciliter; 95% confidence interval [CI], 0.12 to 0.24), which met the prespecified noninferiority margin of -0.75 g per deciliter. During a median follow-up of 2.5 years, a major adverse cardiovascular event occurred in 374 of 1487 patients (25.2%) in the daprodustat group and in 394 of 1477 (26.7%) in the ESA group (hazard ratio, 0.93; 95% CI, 0.81 to 1.07), which also met the prespecified noninferiority margin for daprodustat. The percentages of patients with other adverse events were similar in the two groups. CONCLUSIONS Among patients with CKD undergoing dialysis, daprodustat was noninferior to ESAs regarding the change in the hemoglobin level from baseline and cardiovascular outcomes. (Funded by GlaxoSmithKline; ASCEND-D ClinicalTrials.gov number, NCT02879305.).
PICO Summary
Population
Patients with chronic kidney disease undergoing dialysis (n= 2,964).
Intervention
Daprodustat (n= 1,487).
Comparison
Erythropoiesis-stimulating agent (ESA), (n= 1,477).
Outcome
The mean (±SE) change in the haemoglobin level from baseline to weeks 28 through 52 was 0.28±0.02 g per decilitre in the daprodustat group and 0.10±0.02 g per decilitre in the ESA group (difference, 0.18 g per decilitre, which met the pre-specified non-inferiority margin of -0.75 g per decilitre). During a median follow-up of 2.5 years, a major adverse cardiovascular event occurred in 374 of 1487 patients (25.2%) in the daprodustat group and in 394 of 1477 (26.7%) in the ESA group, which also met the pre-specified non-inferiority margin for daprodustat. The percentages of patients with other adverse events were similar in the two groups.
2.
Audit and feedback to improve laboratory test and transfusion ordering in critical care: a systematic review
Foster M, Presseau J, McCleary N, Carroll K, McIntyre L, Hutton B, Brehaut J
Implement Sci. 2020;15(1):46
-
-
-
-
Editor's Choice
Abstract
BACKGROUND Laboratory tests and transfusions are sometimes ordered inappropriately, particularly in the critical care setting, which sees frequent use of both. Audit and Feedback (A&F) is a potentially useful intervention for modifying healthcare provider behaviors, but its application to the complex, team-based environment of critical care is not well understood. We conducted a systematic review of the literature on A&F interventions for improving test or transfusion ordering in the critical care setting. METHODS Five databases, two registries, and the bibliographies of relevant articles were searched. We included critical care studies that assessed the use of A&F targeting healthcare provider behaviors, alone or in combination with other interventions to improve test and transfusion ordering, as compared to historical practice, no intervention, or another healthcare behaviour change intervention. Studies were included only if they reported laboratory test or transfusion orders, or the appropriateness of orders, as outcomes. There were no restrictions based on study design, date of publication, or follow-up time. Intervention characteristics and absolute differences in outcomes were summarized. The quality of individual studies was assessed using a modified version of the Effective Practice and Organisation of Care Cochrane Review Group's criteria. RESULTS We identified 16 studies, including 13 uncontrolled before-after studies, one randomized controlled trial, one controlled before-after study, and one controlled clinical trial (quasi-experimental). These studies described 17 interventions, mostly (88%) multifaceted interventions with an A&F component. Feedback was most often provided in a written format only (41%), more than once (53%), and most often only provided data aggregated to the group-level (41%). Most studies saw a change in the hypothesized direction, but not all studies provided statistical analyses to formally test improvement. Overall study quality was low, with studies often lacking a concurrent control group. CONCLUSIONS Our review summarizes characteristics of A&F interventions implemented in the critical care context, points to some mechanisms by which A&F might be made more effective in this setting, and provides an overview of how the appropriateness of orders was reported. Our findings suggest that A&F can be effective in the context of critical care; however, further research is required to characterize approaches that optimize the effectiveness in this setting alongside more rigorous evaluation methods. TRIAL REGISTRATION PROSPERO CRD42016051941.
PICO Summary
Population
Healthcare professionals ordering laboratory tests or blood transfusion components for patients in an intensive care unit (16 studies).
Intervention
17 different Audit and Feedback (A&F) interventions to improve laboratory test and transfusion ordering.
Comparison
Usual care (no intervention; historical or concurrent), or any other single or multifaceted behavioral intervention that did not involve A&F (e.g., education, incentives, reminders, or systems-based changes).
Outcome
The included studies described 17 interventions, mostly (88%) multifaceted interventions with an A&F component. Feedback was most often provided in a written format only (41%), more than once (53%), and most often only provided data aggregated to the group-level (41%). Most studies saw a change in the hypothesized direction, but not all studies provided statistical analyses to formally test improvement. Overall study quality was low, with studies often lacking a concurrent control group.