0
selected
-
1.
Eptacog beta efficacy and safety in the treatment and control of bleeding in paediatric subjects (<12 years) with haemophilia A or B with inhibitors
Pipe SW, Hermans C, Chitlur M, Carcao M, Castaman G, Davis JA, Ducore J, Dunn AL, Escobar M, Journeycake J, et al
Haemophilia : the official journal of the World Federation of Hemophilia. 2022
-
-
Free full text
-
Abstract
INTRODUCTION Eptacog beta is a new recombinant activated human factor VII bypassing agent approved in the United States for the treatment and control of bleeding in patients with haemophilia A or B with inhibitors 12 years of age or older. AIM: To prospectively assess in a phase 3 clinical trial (PERSEPT 2) eptacog beta efficacy and safety for treatment of bleeding in children <12 years of age with haemophilia A or B with inhibitors. METHODS Using a randomised crossover design, subjects received initial doses of 75 or 225 μg/kg eptacog beta followed by 75 μg/kg dosing at predefined intervals (as determined by clinical response) to treat bleeding episodes (BEs). Treatment success criteria included a haemostasis evaluation of 'excellent' or 'good' without use of additional eptacog beta, alternative haemostatic agent or blood product, and no increase in pain following the first 'excellent' or 'good' assessment. RESULTS Treatment success proportions in 25 subjects (1-11 years) who experienced 546 mild or moderate BEs were 65% in the 75 μg/kg initial dose regimen (IDR) and 60% in the 225 μg/kg IDR 12 h following initial eptacog beta infusion. By 24 h, the treatment success proportions were 97% for the 75 μg/kg IDR and 98% for the 225 μg/kg IDR. No thrombotic events, allergic reactions, neutralising antibodies or treatment-related adverse events were reported. CONCLUSION Both 75 and 225 μg/kg eptacog beta IDRs provided safe and effective treatment and control of bleeding in children <12 years of age.
-
2.
The safety of activated eptacog beta in the management of bleeding episodes and perioperative haemostasis in adult and paediatric haemophilia patients with inhibitors
Escobar M, Castaman G, Boix SB, Callaghan M, de Moerloose P, Ducore J, Hermans C, Journeycake J, Leissinger C, Luck J, et al
Haemophilia : the official journal of the World Federation of Hemophilia. 2021
-
-
Free full text
-
Abstract
INTRODUCTION Haemophilia patients with inhibitors often require a bypassing agent (BPA) for bleeding episode management. Eptacog beta (EB) is a new FDA-approved recombinant activated human factor VII BPA for the treatment and control of bleeding in haemophilia A or B patients with inhibitors (≥12 years of age). We describe here the EB safety profile from the three prospective Phase 3 clinical trials performed to date. AIM: To assess EB safety, immunogenicity and thrombotic potential in children and adults who received EB for treatment of bleeding and perioperative care. METHODS Using a randomized crossover design, 27 subjects in PERSEPT 1 (12-54 years) and 25 subjects in PERSEPT 2 (1-11 years) treated bleeding episodes with 75 or 225 μg/kg EB initially followed by 75 μg/kg dosing at predefined intervals as determined by clinical response. Twelve PERSEPT 3 subjects (2-56 years) received an initial preoperative infusion of 75 μg/kg (minor procedures) or 200 μg/kg EB (major surgeries) with subsequent 75 μg/kg doses administered intraoperatively and post-operatively as indicated. Descriptive statistics were used for data analyses. RESULTS Sixty subjects who received 3388 EB doses in three trials were evaluated. EB was well tolerated, with no allergic, hypersensitivity, anaphylactic or thrombotic events reported and no neutralizing anti-EB antibodies detected. A death occurred during PERSEPT 3 and was determined to be unlikely related to EB treatment by the data monitoring committee. CONCLUSION Results from all three Phase 3 trials establish an excellent safety profile of EB in haemophilia A or B patients with inhibitors for treatment of bleeding and perioperative use.
-
3.
Assessing options for treating haemophilia with inhibitors
Farrugia A, Hermans C, Franchini M
Haemophilia. 2015;21((3)):307-9.
-
4.
Pharmacokinetic characteristics of factor VIII and IX concentrates – a systematic review
Xi M, Blanchette V, Blatny J, Collins P, Dunn A, Fischer K, Hermans C, Navarro-Ruan T, Kavakli K, Jackson S, et al
Journal of Thrombosis and Haemostasis. 2015;13((Suppl. 2)):357.. Abstract No. PO262-MON.
-
5.
Plasma extraction rate and collection efficiency during therapeutic plasma exchange with Spectra Optia in comparison with Haemonetics MCS+
Lambert C, Gericke M, Smith R, Hermans C
Journal of Clinical Apheresis. 2011;26((1):):17-22.
Abstract
For therapeutic plasma exchange (TPE), continuous and intermittent flow separators are known to be efficient. This study was undertaken to compare the performances of the Spectra Optia, a continuous flow centrifugal apheresis system recently developed by CaridianBCT, with the Haemonetics Multicomponents System (MCS)+ apheresis system based on intermittent flow centrifugation. The primary objective of the study was to compare the time required to exchange one total plasma volume with both separators. The secondary objectives were to determine the plasma exchange efficiency, the plasma extraction rate, the percentage of target exchange volume achieved, and the loss of cellular components. The study involved prospectively paired comparison of 16 TPE on each device performed in patients with chronic diseases treated with TPE. The time required to exchange 1 total plasma volume was 182 ± 36 minutes for MCS+ procedures and 100 ± 20 minutes for the Spectra Optia procedures (P < 0.05, all results presented as mean ± standard deviation). A significantly higher plasma extraction rate was achieved (30.2 ± 4.3 vs 16.8 ± 3.4 mL/min, respectively, P < 0.05), and the plasma exchange efficiency was slightly better with the Spectra Optia compared with the MCS+ procedures (83.4 ± 7.0 vs 80.0 ± 8.5%, P < 0.05). The platelet loss was significantly lower with the Spectra Optia compared with the MCS+ procedures (1.6 ± 2.3 vs 7.5 ± 4.2%, respectively, P < 0.05), whereas the red blood cells loss was comparable. In conclusion, the Spectra Optia has significantly higher extraction rate and exchange efficiency than the MCS+ allowing to remove the same amount of plasma in less time, by processing less blood. It also removes significantly less platelets than the MCS+ separator.
-
6.
ReFacto and Advate: a single-dose, randomized, two-period crossover pharmacokinetics study in subjects with haemophilia A
Di Paola J, Smith MP, Klamroth R, Mannucci PM, Kollmer C, Feingold J, Kessler C, Pollmann H, Morfini M, Udata C, et al
Haemophilia. 2007;13((2):):124-30.
Abstract
ReFacto is a recombinant B-domain-deleted, monoclonal antibody-purified, solvent-detergent-treated factor VIII (BDDrFVIII) with no albumin added to the final formulation. Although ReFacto has been shown to be bioequivalent to a plasma-derived FVIII product (Hemophil-M) in a randomized, crossover pharmacokinetic (PK) study, the comparability of ReFacto with the full-length (complete sequence) recombinant FVIII (FLrFVIII, Advate) product has not been previously examined in this manner. The primary objective of this study was to compare the PKs of ReFacto with those of Advate in patients with severe haemophilia A. This was a third-party unblinded, randomized, multicentre, two-period crossover PKs study of ReFacto and Advate in subjects with severe haemophilia A (FVIIIC < or =1%). Blood samples were collected over a 48-h period after i. v. administration of each of the FVIII products. FVIIIC was determined using the chromogenic substrate assay (CSA) in a central laboratory. The plasma FVIIIC PK parameters of ReFacto and Advate were determined using non-compartmental analysis. Bioequivalence was assessed on maximum plasma concentration (C(max)) and the area under the plasma concentration vs. time curves (AUCs) using an anova. The two products were judged to be equivalent if the 90% confidence limits of the ratio of the geometric mean values of C(max) and AUCs fell within the interval of 80-125%. Results from this PKs comparison of two different rFVIII products, using chromogenic substrate assay to measure FVIIIC, showed that ReFacto and Advate are bioequivalent to each other.