1.
Audit and feedback to improve laboratory test and transfusion ordering in critical care: a systematic review
Foster M, Presseau J, McCleary N, Carroll K, McIntyre L, Hutton B, Brehaut J
Implement Sci. 2020;15(1):46
-
-
-
-
Editor's Choice
Abstract
BACKGROUND Laboratory tests and transfusions are sometimes ordered inappropriately, particularly in the critical care setting, which sees frequent use of both. Audit and Feedback (A&F) is a potentially useful intervention for modifying healthcare provider behaviors, but its application to the complex, team-based environment of critical care is not well understood. We conducted a systematic review of the literature on A&F interventions for improving test or transfusion ordering in the critical care setting. METHODS Five databases, two registries, and the bibliographies of relevant articles were searched. We included critical care studies that assessed the use of A&F targeting healthcare provider behaviors, alone or in combination with other interventions to improve test and transfusion ordering, as compared to historical practice, no intervention, or another healthcare behaviour change intervention. Studies were included only if they reported laboratory test or transfusion orders, or the appropriateness of orders, as outcomes. There were no restrictions based on study design, date of publication, or follow-up time. Intervention characteristics and absolute differences in outcomes were summarized. The quality of individual studies was assessed using a modified version of the Effective Practice and Organisation of Care Cochrane Review Group's criteria. RESULTS We identified 16 studies, including 13 uncontrolled before-after studies, one randomized controlled trial, one controlled before-after study, and one controlled clinical trial (quasi-experimental). These studies described 17 interventions, mostly (88%) multifaceted interventions with an A&F component. Feedback was most often provided in a written format only (41%), more than once (53%), and most often only provided data aggregated to the group-level (41%). Most studies saw a change in the hypothesized direction, but not all studies provided statistical analyses to formally test improvement. Overall study quality was low, with studies often lacking a concurrent control group. CONCLUSIONS Our review summarizes characteristics of A&F interventions implemented in the critical care context, points to some mechanisms by which A&F might be made more effective in this setting, and provides an overview of how the appropriateness of orders was reported. Our findings suggest that A&F can be effective in the context of critical care; however, further research is required to characterize approaches that optimize the effectiveness in this setting alongside more rigorous evaluation methods. TRIAL REGISTRATION PROSPERO CRD42016051941.
PICO Summary
Population
Healthcare professionals ordering laboratory tests or blood transfusion components for patients in an intensive care unit (16 studies).
Intervention
17 different Audit and Feedback (A&F) interventions to improve laboratory test and transfusion ordering.
Comparison
Usual care (no intervention; historical or concurrent), or any other single or multifaceted behavioral intervention that did not involve A&F (e.g., education, incentives, reminders, or systems-based changes).
Outcome
The included studies described 17 interventions, mostly (88%) multifaceted interventions with an A&F component. Feedback was most often provided in a written format only (41%), more than once (53%), and most often only provided data aggregated to the group-level (41%). Most studies saw a change in the hypothesized direction, but not all studies provided statistical analyses to formally test improvement. Overall study quality was low, with studies often lacking a concurrent control group.
2.
Effect of blood donor characteristics on transfusion outcomes: a protocol for systematic review and meta-analysis
Chasse M, English SW, McIntyre L, Knoll G, Shehata N, Forster A, Wilson K, van Walraven C, Tinmouth A, Fergusson DA
Systems Review. 2014;3((1):):28.
Abstract
BACKGROUND Optimal selection of blood donors is of paramount importance in ensuring the safety of blood products. The current selection process is concerned principally with the safety of the blood donor and the safety of the patient that receives the blood. Recent evidence suggests that the characteristics of the donor may affect transfusion outcomes for the recipient. METHODS We will conduct a systematic review of the association between major blood donor characteristics and red blood cell (RBC) transfusion outcomes. The primary objective is to assess the association of blood donor characteristics and the risk of adverse short-term and long-term clinical outcomes after RBC transfusion. We will search MEDLINE, EMBASE, Cochrane Central databases, as well as perform manual searches of top transfusion medical journals for prospective and retrospective studies. Study characteristics will be reported and the methodological quality of studies will be assessed. When appropriate, we will provide pooled odds ratio with 95% confidence intervals of the effect estimates, study clinical heterogeneity using pre-defined sensitivity and subgroup analyses, and study statistical heterogeneity using the I2 test. DISCUSSION The results of this systematic review will provide an evidence base regarding the potential clinical effects of donor characteristics on transfusion recipients to better guide policy and clinical practice. The evidence gathered from this review will also identify strengths and weaknesses of published studies regarding donor characteristics and transfusion outcomes and will identify knowledge gaps to inform future research in this field of transfusion medicine. TRIAL REGISTRATION PROSPERO Registration Number: CRD42013006726.