1.
Personalized tourniquet pressure may be a better choice than uniform tourniquet pressure during total knee arthroplasty: A PRISMA-compliant systematic review and meta-analysis of randomized-controlled trials
Sun C, Yang X, Zhang X, Ma Q, Yu P, Cai X, Zhou Y
Medicine. 2022;101(8):e28981
-
-
Free full text
-
Abstract
BACKGROUND Pneumatic tourniquets are widely used in total knee arthroplasty (TKA). Some surgeons prefer a uniform tourniquet inflation pressure (UTIP) for all patients; others use personalized tourniquet inflation pressures (PTIP) based on systolic blood pressure and limb occlusion pressure. However, no consensus exists regarding the optimal mode of inflation pressure during TKA. This review aimed to appraise if personalized tourniquet inflation pressures are better than uniform tourniquet inflation. METHODS The databases (Web of Science, Embase, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, Wanfang) were searched on March 2021 to systematically identify and screen the literature for randomized controlled trials involving PTIP and UTIP during total knee arthroplasty. RESULTS Thirteen randomized controlled trials, involving 1204 TKAs (1201 patients) were included in the systematic review. The meta-analysis identified a trend toward less visual analogue scale (VAS) score at rest with PTIP group at 1 day (P = .002), 2 to 3 days (P = .01), and less VAS score at activity 1 day (P < .0001), 2 to 3 days after the operation (P < .00001), and discharge (P < .0001). No significant difference was found between the groups in terms of VAS score at rest when discharge (P = 1.0). We also found no significant difference in terms of intraoperative blood loss (P = .48), total blood loss (P = .15), lower limb vein thrombosis (P = .42), and thigh bullae (P = .17). However, in the PTIP group, we found a significant higher hospital for special surgery (HSS) score (P = .007), broader knee Range of motion (P = .02), less rate of thigh ecchymosis (P = .00001), and shorter thigh circumference at 1 day (P = .006), 2 to 3 days (P = .0005), and discharge (P = .02). CONCLUSION PTIP provides a similar bloodless surgical field compared with the conventional UTIP. Furthermore, PTIP provides less pain intensity, thigh circumference, rate of thigh ecchymosis, higher hospital for special surgery, and better initial recovery of knee flexion in total knee arthroplasty. Therefore, we recommend using a PTIP method during TKA. More adequately powered and better-designed randomized controlled trials studies with long-term follow-up are required to produce evidence-based guidelines regarding the PTIP method.
2.
Comparison of Application Effects of Different Hemostasis Methods After Ischemic Cerebrovascular Intervention
Zhou Y, Xu C
Frontiers in surgery. 2022;9:850139
Abstract
OBJECTIVE To explore the effects of two different hemostasis methods, namely, arterial compression devices and vascular closure devices, in the ischemic cerebrovascular intervention to provide a theoretical basis for clinical selection of hemostasis methods. METHODS A total of 302 patients who underwent ischemic cerebrovascular intervention in our hospital from January 2016 to December 2020 were selected as the research subjects and randomly divided into the control group (n = 151) and the observation group (n = 151). The patients in both groups underwent cerebrovascular intervention. The patients in the control group were treated with an artery compressor for hemostasis after the operation, while those in the observation group were treated with vascular closure devices for hemostasis. The hemostatic indexes and vascular parameters at the puncture site before and after the operation were compared between the two groups. The comfort level of the patients was assessed at 6, 12, and 24 h after the operation with the Kolcaba Comfort Scale score, and the postoperative complications were recorded. RESULTS There was no significant difference in the success rate of hemostasis between the two groups (p > 0.05). The hemostatic time and immobilization time of (2.69 ± 0.62) min and (4.82 ± 0.93) h in the observation group were lower than those in the control group with (16.24 ± 3.58) min and (7.94 ± 1.86) h (p < 0.05). The differences in the minimum inner diameter of the puncture site and its nearby vessels and the peak velocity of blood flow between the two groups before and after the operation were not statistically significant within or between groups (p > 0.05). The scores of the Kolcaba comfort scale in the observation group (80.16 ± 8.49) and (93.65 ± 9.26) at 6 and 12 h, respectively, after the operation, were higher than those in the control groups (72.08 ± 7.54) and (85.49 ± 8.63) (p < 0.05). The 24 h postoperative Kolcaba comfort scale score was (97.54 ± 9.86) in the observation group and (96.82 ± 9.64) in the control group, and the difference was not statistically significant (p > 0.05). In the control group, there were 7 cases of dysuria, 12 cases of low back pain, 14 cases of sleep disorder, 20 cases of mental stress, and 5 cases of wound bleeding, and the total incidence of complications was 38.41% (58/151). In the observation group, there were 4 cases of dysuria, 8 cases of low back pain, 10 cases of sleep disorder, 14 cases of mental stress, and 3 cases of wound bleeding, and the total incidence of complications was 25.83% (39/151). The total incidence of complications in the observation group was lower than that in the control group (p < 0.05). CONCLUSION For patients with ischemic cerebrovascular disease undergoing femoral artery puncture intervention, the use of vascular closure devices can stop the bleeding quickly, which can significantly shorten the bleeding time, and the postoperative braking time of patients is short, with high comfort and fewer complications.
3.
The impact of tourniquet on tibial bone cement penetration in different zones in primary total knee arthroplasty: a meta-analysis
Sun C, Yang X, Zhang X, Ma Q, Yu P, Cai X, Zhou Y
Journal of orthopaedic surgery and research. 2021;16(1):198
Abstract
BACKGROUND Cement mantle penetration and the cement-bone interface strength were critical to a successful primary total knee arthroplasty (TKA). It remained unclear whether decreased blood and fat in the cancellous bone achieved with the use of a tourniquet increases tibial cement mantle penetration in different zones on AP and lateral view in TKA according to criteria defined by the Knee Society Scoring System (KSS). The purpose of this study was to determine whether tourniquet use influences tibial cement mantle penetration in different zones on AP and lateral view in TKA according to KSS. METHODS We conducted a meta-analysis to identify studies involving the impact of tourniquet use and no tourniquet use on tibial bone cement penetration in primary TKA in electronic databases, including Web of Science, Embase, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, VIP, Wanfang database, up to January 2021. Finally, we identified 1231 patients (1231 knees) assessed in twelve studies. RESULTS Tourniquet use increases the cumulative cement mantle penetration (P < 0.00001), mean cement mantle penetration (P = 0.004), and cement mantle in zone 3(P < 0.0001) on AP view. However, there were no significant differences in cement mantle in zone 1(P = 0.5), zone 2(P =0 .54), zone 4(P = 0.07) on AP view, and zone 1(P = 0.32), zone 2(P = 0.38) on lateral view between two groups. There were also no significant differences in length of surgery(P = 0.7), change in hemoglobin(P = 0.4), transfusion rates(P = 0.47), and complications such as muscular calf vein thrombosis(P = 0.21), superficial infection (P = 0.72), and deep vein thrombosis (P = 0.66) between two groups. CONCLUSION The application of a tourniquet increases the thickness of the tibial bone cement penetration-the increase in the thickness of bone cement penetration mainly located in zone 3 on the anteroposterior (AP) view.
4.
Effect of infrahepatic inferior vena cava clamping on bleeding during hepatic resection: a meta-analysis
Zhou Y, Zhang Z, Wan T
Asian Journal of Surgery. 2017;41((6):):523-529
Abstract
This meta-analysis aimed to explore the effect of infrahepatic vena cava (IVC) clamping on bleeding during hepatic resection. PubMed and Embase databases were searched systematically to identify randomized controlled trials (RCTs) comparing infrahepatic IVC clamping to IVC nonclamping during hepatic resection. A random-effects model was used to calculate weight and outcome measures. Five RCTs involving a total of 596 patients were identified for inclusion: 299 in infrahepatic IVC clamping group and 297 in nonclamping group. Infrahepatic IVC clamping was associated with a statistically significant reduction in total intraoperative blood loss (weighted mean difference [WMD] -181.72, 95% confidence interval [95% CI] -329.03 to -34.4; P = 0.02) and blood loss during parenchymal transaction (WMD -160.58, 95% CI, -261.9 to -59.27; P = 0.002). Postoperative morbidity, mortality, and hospital stay were comparable in both groups. Data from currently available literature suggest that infrahepatic IVC clamping is a safe procedure that facilitates intraoperative bleeding control during hepatic resection.