0
selected
-
1.
International guidelines regarding the role of IVIG in the management of Rh- and ABO-mediated haemolytic disease of the newborn
Lieberman L, Lopriore E, Baker JM, Bercovitz RS, Christensen RD, Crighton G, Delaney M, Goel R, Hendrickson JE, Keir A, et al
British journal of haematology. 2022
-
-
Free full text
-
Abstract
Haemolytic disease of the newborn (HDN) can be associated with significant morbidity. Prompt treatment with intensive phototherapy (PT) and exchange transfusions (ETs) can dramatically improve outcomes. ET is invasive and associated with risks. Intravenous immunoglobulin (IVIG) may be an alternative therapy to prevent use of ET. An international panel of experts was convened to develop evidence-based recommendations regarding the effectiveness and safety of IVIG to reduce the need for ETs, improve neurocognitive outcomes, reduce bilirubin level, reduce the frequency of red blood cell (RBC) transfusions and severity of anaemia, and/or reduce duration of hospitalization for neonates with Rh or ABO-mediated HDN. We used a systematic approach to search and review the literature and then develop recommendations from published data. These recommendations conclude that IVIG should not be routinely used to treat Rh or ABO antibody-mediated HDN. In situations where hyperbilirubinaemia is severe (and ET is imminent), or when ET is not readily available, the role of IVIG is unclear. High-quality studies are urgently needed to assess the optimal use of IVIG in patients with HDN.
-
2.
Plasma and Platelet Transfusion Strategies in Critically Ill Children With Malignancy, Acute Liver Failure and/or Liver Transplantation, or Sepsis: From the Transfusion and Anemia EXpertise Initiative-Control/Avoidance of Bleeding
Lieberman L, Karam O, Stanworth SJ, Goobie SM, Crighton G, Goel R, Lacroix J, Nellis ME, Parker RI, Steffen K, et al
Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies. 2022;23(Supplement 1 1S):e37-e49
-
-
Free full text
-
Abstract
OBJECTIVES To present the consensus statements with supporting literature for plasma and platelet transfusions in critically ill neonates and children with malignancy, acute liver disease and/or following liver transplantation, and sepsis and/or disseminated intravascular coagulation from the Transfusion and Anemia EXpertise Initiative-Control/Avoidance of Bleeding. DESIGN Systematic review and consensus conference of international, multidisciplinary experts in platelet and plasma transfusion management of critically ill children. SETTING Not applicable. PATIENTS Critically ill neonates and children with malignancy, acute liver disease and/or following liver transplantation, and sepsis and/or disseminated intravascular coagulation. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS A panel of 13 experts developed evidence-based and, when evidence was insufficient, expert-based statements for plasma and platelet transfusions in critically ill neonates and children with malignancy, acute liver disease and/or following liver transplantation, and sepsis and/or disseminated intravascular coagulation. These statements were reviewed and ratified by the 29 Transfusion and Anemia EXpertise Initiative-Control/Avoidance of Bleeding experts. A systematic review was conducted using MEDLINE, EMBASE, and Cochrane Library databases, from inception to December 2020. Consensus was obtained using the Research and Development/University of California, Los Angeles Appropriateness Method. Results were summarized using the Grading of Recommendations Assessment, Development, and Evaluation method. We developed 12 expert consensus statements. CONCLUSIONS In the Transfusion and Anemia EXpertise Initiative-Control/Avoidance of Bleeding program, the current absence of evidence for use of plasma and/or platelet transfusion in critically ill children with malignancy, acute liver disease and/or following liver transplantation, and sepsis means that only expert consensus statements are possible for these areas of practice.
-
3.
What Laboratory Tests and Physiologic Triggers Should Guide the Decision to Administer a Platelet or Plasma Transfusion in Critically Ill Children and What Product Attributes Are Optimal to Guide Specific Product Selection? From the Transfusion and Anemia EXpertise Initiative-Control/Avoidance of Bleeding
Delaney M, Karam O, Lieberman L, Steffen K, Muszynski JA, Goel R, Bateman ST, Parker RI, Nellis ME, Remy KE
Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies. 2022;23(Supplement 1 1S):e1-e13
-
-
Free full text
-
Abstract
OBJECTIVES To present consensus statements and supporting literature for plasma and platelet product variables and related laboratory testing for transfusions in general critically ill children from the Transfusion and Anemia EXpertise Initiative-Control/Avoidance of Bleeding. DESIGN Systematic review and consensus conference of international, multidisciplinary experts in platelet and plasma transfusion management of critically ill children. SETTING Not applicable. PATIENTS Critically ill pediatric patients at risk of bleeding and receiving plasma and/or platelet transfusions. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS A panel of 10 experts developed evidence-based and, when evidence was insufficient, expert-based statements for laboratory testing and blood product attributes for platelet and plasma transfusions. These statements were reviewed and ratified by the 29 Transfusion and Anemia EXpertise Initiative - Control/Avoidance of Bleeding experts. A systematic review was conducted using MEDLINE, EMBASE, and Cochrane Library databases, from inception to December 2020. Consensus was obtained using the Research and Development/University of California, Los Angeles Appropriateness Method. Results were summarized using the Grading of Recommendations Assessment, Development, and Evaluation method. We developed five expert consensus statements and two recommendations in answer to two questions: what laboratory tests and physiologic triggers should guide the decision to administer a platelet or plasma transfusion in critically ill children; and what product attributes are optimal to guide specific product selection? CONCLUSIONS The Transfusion and Anemia EXpertise Initiative-Control/Avoidance of Bleeding program provides some guidance and expert consensus for the laboratory and blood product attributes used for decision-making for plasma and platelet transfusions in critically ill pediatric patients.
-
4.
Vitamin K antagonist reversal strategies: Systematic review and network meta-analysis from the AABB
Pagano MB, Foroutan F, Goel R, Allen ES, Cushing MM, Garcia DA, Hopkins CK, Klein K, Raval JS, Cohn CS
Transfusion. 2022
-
-
-
-
Editor's Choice
Abstract
BACKGROUND Anticoagulation requires urgent reversal in cases of life-threatening bleeding or invasive procedures. STUDY DESIGN AND METHODS Network meta-analysis for comparing the safety and efficacy of warfarin reversal strategies including plasma and prothrombin complex concentrates (PCCs). RESULTS Seven studies including 594 subjects using reversal agents plasma, 3-factor-PCC (Uman Complex and Konyne), and 4-factor-PCC (Beriplex/KCentra, Octaplex, and Cofact) met inclusion criteria. Compared with plasma, patients receiving Cofact probably have a higher rate of international normalized ratio (INR) correction (risk difference [RD] 499 more per 1000 patients, 95% confidence interval [CI], 176-761, low certainty[LC]); higher reversal of bleeding (323 more per 1000 patients, 11-344 more, LC); and fewer transfusion requirements (0.96 fewer units, 1.65-0.27 fewer, LC). Patients receiving Beriplex/KCentra probably have a higher rate of INR correction (476 more per 1000 patients, 332-609 more, LC); higher reversal of bleeding (127 more per 1000 patients, 43 fewer to 236 more); and similar transfusion requirements (0.01 fewer units, 0.31 fewer to 0.28 more, high/moderate certainty). Patients receiving Octaplex probably have a higher rate of INR correction (RD 579 more per 1000 patients, 189-825 more, LC). CONCLUSIONS PCCs probably provide an advantage in INR reversal compared to plasma. There was no added risk of adverse events with PCCs.
PICO Summary
Population
Adult patients in need of urgent warfarin reversal due to either bleeding or an imminent invasive procedure (7 studies, n= 594).
Intervention
3 factor PCC (Uman Complex, Konyne), and 4 factor PCC (Beriplex/KCentra, Octaplex, and Cofact).
Comparison
Plasma.
Outcome
Compared with plasma, patients receiving Cofact probably had a higher rate of international normalized ratio (INR) correction, higher reversal of bleeding, and fewer transfusion requirements (low certainty). Patients receiving Beriplex/KCentra probably had a higher rate of INR correction (low certainty), higher reversal of bleeding; and similar transfusion requirements (high/moderate certainty). Patients receiving Octaplex probably had a higher rate of INR correction (low certainty).
-
5.
Executive Summary of Recommendations and Expert Consensus for Plasma and Platelet Transfusion Practice in Critically Ill Children: From the Transfusion and Anemia EXpertise Initiative-Control/Avoidance of Bleeding (TAXI-CAB)
Nellis ME, Karam O, Valentine SL, Bateman ST, Remy KE, Lacroix J, Cholette JM, Bembea MM, Russell RT, Steiner ME, et al
Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies. 2022;23(1):34-51
-
-
Free full text
-
Abstract
OBJECTIVES Critically ill children frequently receive plasma and platelet transfusions. We sought to determine evidence-based recommendations, and when evidence was insufficient, we developed expert-based consensus statements about decision-making for plasma and platelet transfusions in critically ill pediatric patients. DESIGN Systematic review and consensus conference series involving multidisciplinary international experts in hemostasis, and plasma/platelet transfusion in critically ill infants and children (Transfusion and Anemia EXpertise Initiative-Control/Avoidance of Bleeding [TAXI-CAB]). SETTING Not applicable. PATIENTS Children admitted to a PICU at risk of bleeding and receipt of plasma and/or platelet transfusions. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS A panel of 29 experts in methodology, transfusion, and implementation science from five countries and nine pediatric subspecialties completed a systematic review and participated in a virtual consensus conference series to develop recommendations. The search included MEDLINE, EMBASE, and Cochrane Library databases, from inception to December 2020, using a combination of subject heading terms and text words for concepts of plasma and platelet transfusion in critically ill children. Four graded recommendations and 49 consensus expert statements were developed using modified Research and Development/UCLA and Grading of Recommendations, Assessment, Development, and Evaluation methodology. We focused on eight subpopulations of critical illness (1, severe trauma, intracranial hemorrhage, or traumatic brain injury; 2, cardiopulmonary bypass surgery; 3, extracorporeal membrane oxygenation; 4, oncologic diagnosis or hematopoietic stem cell transplantation; 5, acute liver failure or liver transplantation; 6, noncardiac surgery; 7, invasive procedures outside the operating room; 8, sepsis and/or disseminated intravascular coagulation) as well as laboratory assays and selection/processing of plasma and platelet components. In total, we came to consensus on four recommendations, five good practice statements, and 44 consensus-based statements. These results were further developed into consensus-based clinical decision trees for plasma and platelet transfusion in critically ill pediatric patients. CONCLUSIONS The TAXI-CAB program provides expert-based consensus for pediatric intensivists for the administration of plasma and/or platelet transfusions in critically ill pediatric patients. There is a pressing need for primary research to provide more evidence to guide practitioners.
-
6.
Tourniquet Use Does Not Affect Functional Outcomes or Pain After Total Knee Arthroplasty: A Prospective, Double-Blinded, Randomized Controlled Trial
Goel R, Rondon AJ, Sydnor K, Blevins K, O'Malley M, Purtill JJ, Austin MS
The Journal of bone and joint surgery. American volume. 2019;101(20):1821-1828
Abstract
BACKGROUND The use of a tourniquet during total knee arthroplasty (TKA) is controversial. Pain and return to function are believed, by some, to be influenced by the use of a tourniquet. The hypothesis of this study was that use of a tourniquet would delay postoperative functional recovery and increase pain as compared with no tourniquet use. METHODS Two hundred patients were recruited for this prospective, double-blinded, randomized controlled trial. Patients were randomized to undergo TKA either with a tourniquet (100 patients) or without one (100 patients) and blinded to group allocation. Primary outcome measures were functional assessment testing using the Timed Up & Go (TUG) test and visual analog scale (VAS) pain scores. Secondary outcome measures included the stair-climb test, blood loss, surgical field visualization, and range of motion. Outcome measures were completed preoperatively, in the hospital, and postoperatively at a first and a second follow-up. The minimal detectable change, Student t test, Fisher exact test, and nonasymptotic chi-square analysis with an alpha of p < 0.05 were used to determine significance. RESULTS The no-tourniquet group had more calculated blood loss (1,148.02 mL compared with 966.64 mL; p < 0.001) and more difficulty with surgical field visualization (p < 0.0001). The tourniquet group had greater knee extension at the first follow-up (-7 degrees compared with -9 degrees ; p = 0.044). CONCLUSIONS Tourniquet use during TKA significantly decreases blood loss and does not adversely affect early postoperative outcomes. Tourniquet use during routine TKA is safe and effective, and concerns about deleterious effects on function and pain may not be justified. LEVEL OF EVIDENCE Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.